All Belden Chemical Resistant Floor Brick are manufactured to conform to or exceed ASTM C-279, and are generally available in Type II designation. In some cases Type III are available. Minimum requirements regarding the ASTM C-279 specification standards are shown in the following table:

Properties TYPE I TYPE II TYPE III Method of Test
Modulus of
Rupture Minimum PSI
1250 1250 1250 ASTM Designation C67
Water Absorption
Maximum % by 2 hr.
Boiling Test
6.0 - 7.0% 4.0 - 5.0% 1.0 - 1.5% ASTM Designation C20
H2SO4 Solubility
Maximum % &
Weight Loss
20 12 8 ASTM Designation C279
Size Variances +/- 3% +/- 3% +/- 3% ASTM Designation C67
Tolerances on
Warpage
8" & Under

Over 8" - 12", Incl.
Table 2
C279-88

Table 2
C279-88
Table 2
C279-88

Table 2
C279-88
Table 2
C279-88

Table 2
C279-88
ASTM Designation C67


ASTM Designation C67

The information provided above has been furnished as a general guide-line for the design of chemical resistant construction. We cannot guarantee the data reported nor can we assume any liability in connection with its use. Please contact The Belden Brick Company for specific recommendations.

Belden Chemical Resistant Floor Brick is manufactured to conform to the specification requirements of both ASTM C-279 and ASTM C-410 (industrial floor brick). Whenever close dimensional tolerances or minimal distortion is required, ASTM C-410, Tables II and III should be used for the dimensional standards of the specification.

PHYSICAL AND CHEMICAL REQUIREMENTS
  Modulus of Rupture
(Brick or Tile Flatwise)
min. PSI (MPa)
Water Absorption
Maximum % by 2 hr.
Boiling Test
H2SO4 Solubility
Maximum %
Weight Loss
Designation      

Average of 5
Brick or Tile
Low Individual
Average of 5
Brick or Tile
High Individual
Average of 5
Brick or Tile
Type I 1250 (8.6) 1000 (6.9) 6.0 7.0 20
Type II 1250 (8.6) 1000 (6.9) 4.0 5.0 12
Type II 1250 (8.6) 1000 (6.9) 1.0 1.5 8


PHYSICAL PROPERTIES & COMPARISON TABLE-VERTICAL FIBRE FLOOR BRICK
Technical Data Belden-Vertical Fibre
Floor Brick Type II
ASTM C-279 TYPE II</td> ASTM C-410 TYPE H Fed. Spec.
SST-308B Class C
Max. Permissible
Variations in
Dimensions
(Largest to Smallest)
1/8" 3% +/- 3/16" -
Max. Permissible
Deviation of
Face Distortion (in.)
1/32" 3/32" 1/16" 9/64"
Compression (PSI)(1) 18,860 None None None
Modulus of Rupture (PSI) 2570 1250 1000 None
Coefficient of Expansion
in./in./°Fx10(6)
2.4 - 3.0 None None None
Tensile Strength (PSI)(2) 3195 - 3390 None None None
Modulus of Elasticity
(PSI)(3)
6.48-7.97x10(6) None None None
Absorption - 2 Hr. Boil 3.9% 6.0 Max. None 5.0 Max.
Acid Solubility
(% of Loss)
(h2So4-48 Hr. Boil)
2.2 12.0 Max. 20.0 Max. None
Tabor Abrasion
Wear Index(4)
83 None None 25 Min.
Abrasion Resistance Index(5) .0114 None None None


NOTES:
1. Applicable Testing Specification Procedure - ASTM C67
2. Applicable Testing Specification Procedure - ASTM C885
3. Applicable Testing Specification Procedure - ASTM C1006
4. Conforms Under Test Method - ASTM C501